Frage

If I enable 32bit applications for a site in IIS 8. i get the following error:

500 - Internal server error. There is a problem with the resource you are looking for, and it cannot be displayed.

pl help.

War es hilfreich?

Lösung

The resolution found to this is to remove the following modules from the iis manager:

1) DynamicCompressionModule 2) StaticCompressionModule


To do it follow the below steps in iis manager:

step 1: iis home - modules - unlock these two modules step 2: sites - website home - modules - remove these two modules


Now in application pools – select the application pool – Advanced Settings – Change the ‘Enable 32-Bit Applications’ to true


This would avoid the internal server error: “500 - Internal server error. There is a problem with the resource you are looking for, and it cannot be displayed.”

To narrow down on the error for finding the specific error; the following should be carried out before the above steps:

In iis manager – Sites – website home – Error pages – Open Feature – select the status code 500 – Edit Feature Settings… - Select Detailed errors and click OK

This would give the detailed error message as below (using it the exact modules that causes the error can be found; earlier we only got the error message: “500 - Internal server error. There is a problem with the resource you are looking for, and it cannot be displayed.”):

HTTP Error 500.19 - Internal Server Error The requested page cannot be accessed because the related configuration data for the page is invalid. Most likely causes: • The worker process is unable to read the applicationhost.config or web.config file. • There is malformed XML in the applicationhost.config or web.config file. • The server cannot access the applicationhost.config or web.config file because of incorrect NTFS permissions. Things you can try: • Look in the event logs for information about why the configuration files are not readable. • Make sure the user identity specified for the application pool, or the authenticated user, has the required permissions to access the web.config file. Detailed Error Information: Module DynamicCompressionModule Notification SendResponse Handler Not yet determined Error Code 0x804500c1 Requested URL http://webaddress.com/

Physical Path X:/Path Logon Method Not yet determined Logon User Not yet determined

More Information: This error occurs when there is a problem reading the configuration file for the Web server or Web application. In some cases, the event logs may contain more information about what caused this error. View more information »