Question

I have a few related selects that work perfectly on a testing server with very loose security (basically just a simple default install of CF 10).

I have tried to implement the CF 10 lockdown guide on the production server and all seems well, except that related select don't work. That is, the first select in the chain doesn't populate and therefore, none of the related selects populate either.

I even recreated Ben Forta's art media example: perfect on the testing server, no triggering in production.

All other CFC functions seem to work: SELECT and INSERT queries are just fine. Only CFSELECTs with bindings are hosed. I pretty sure that the problem is a server configuration. The same pages worked just fine on our old CF 9 box. Any ideas would be helpful.

Was it helpful?

Solution

My advice to you would be to NOT use cfselect or any other UI stuff in ColdFsuion - It only causes more headaches than it gets rid of.

That being said, if you followed the lockdown guide, you should have limited access to the CFIDE directory - which is needed for any of the ColdFusion UI stuff. There is an option in CF Admin to use a 'custom' path for the scripts ColdFusion uses - it is on the main Settings page. Set this value and create a virtual directory in IIS with the same name pointing to the {cfroot}CFIDE/scripts directory.

Licensed under: CC-BY-SA with attribution
Not affiliated with StackOverflow