Question

Is there a way to set ResetSeqNumFlag=Y using the Quickfix config?

Was it helpful?

Solution

Look at the "Miscellaneous" section of the manual:

http://www.quickfixj.org/quickfixj/usermanual/1.5.1/usage/configuration.html

There are several reset options (Logon/Logout/Disconnect/Error etc.)

OTHER TIPS

As I know there is no way to do it.

I had a situation when after logon I got logout message with the text

MsgSeqNum too low, expecting 194 but received 16 Logon

I have looked through the manual and played with reset options in config:

ResetOnLogout=Y
ResetOnLogon=Y
ResetOnDisconnect=Y
ResetOnError=Y

None of them adds ResetSeqNumFlag=Y to logon message. So I had to do it manually at #toAdmin method.