Question

The way I do it is to read the data from block 3 and select the proper bytes from the result to get the access condition (e.g.:FF 07 80 69)

In this way, if I don't have keyA or keyB, I can not get the data from block 3.

Is there another way to get the access condition?

Was it helpful?

Solution

No, the only way to read any of the blocks of MIFARE Classic is to first authenticate with Key A or Key B. There is no shortcut.

Licensed under: CC-BY-SA with attribution
Not affiliated with StackOverflow