Question

[anydac][DApt]-400.Fetch command fetched[0] instead of [1] record, Possible reasons:update table does not have PK or row identifier,record has been changed/deleted by another user,

when executing

SingleTestRunADQuery.Append();
SingleTestRunADQuery.FieldByName('run_id').Value := StartRecordingButton.Tag;
SingleTestRunADQuery.FieldByName('ph_value').Value := FloatToStr(ph_reading);
SingleTestRunADQuery.FieldByName('conductivity_value').Value := conductivity_reading;
SingleTestRunADQuery.FieldByName('cod_value').Value := cod_reading;
SingleTestRunADQuery.Post();

on

mysql> describe measurements;
+------------------------+-----------+------+-----+-------------------+-------+
| Field                  | Type      | Null | Key | Default           | Extra |
+------------------------+-----------+------+-----+-------------------+-------+
| run_id                 | int(11)   | NO   | MUL | NULL              |       |
| measurement_time_stamp | timestamp | NO   | PRI | CURRENT_TIMESTAMP |       |
| ph                     | float     | NO   |     | NULL              |       |
| conductivity           | float     | NO   |     | NULL              |       |
| cod                    | float     | NO   |     | NULL              |       |
+------------------------+-----------+------+-----+-------------------+-------+
5 rows in set (0.03 sec)

as you can see, the table does have a PK. Also, the program is single-threaded and only one copy is running, so no one else is updating.

I set SingleTestRunADQuery.MasterFields=run_id and IndexFieldNames=run_id as that is the PK of table which holds a summary of all test runs. The second table hold the measurements taken during tests, with run_id giving all the measurements for one test run (I only added PK on tiemstamp to get rid of this error, but it didn't work and can be removed, I guess).

In case it helps, here's the master data source:

mysql> describe test_runs;
+------------------+-------------+------+-----+-------------------+----------------+
| Field            | Type        | Null | Key | Default           | Extra          |
+------------------+-------------+------+-----+-------------------+----------------+
| run_id           | int(11)     | NO   | PRI | NULL              | auto_increment |
| start_time_stamp | timestamp   | NO   |     | CURRENT_TIMESTAMP |                |
| end_time_stamp   | timestamp   | YES  |     | NULL              |                |
| description      | varchar(64) | YES  |     | NULL              |                |
+------------------+-------------+------+-----+-------------------+----------------+
4 rows in set (0.05 sec)

Any idea what's wrong?


[Update] @ mj2008 points out that some fields have different names. This is for historical reasons (I am still trying something out & don't want to change yet), hoever these are adapted by the query:

SELECT run_id,
       measurement_time_stamp, 
       ph as ph_value, 
       conductivity as conductivity_value, 
       cod as cod_value

FROM photo_catalytic.measurements

ORDER BY measurement_time_stamp DESC
Was it helpful?

Solution

I'm not sure that is correct to have TIMESTAMP field as PRIMARY KEY. It will automatically change on every UPDATE.

OTHER TIPS

Check out to the TFields property of Query component, through "Fields Editor" option. check that "Key Fields" has a ProviderFlags.pfInKey property set to true.

This applies today to FireDac components.

You should change the connection properties as follows: Try setting UpdateOptions.RefreshMode to rmManual.

enter image description here