Domanda

I'm using OpenIMPI library for managing Shelf Manager (Pigeon Point ShMM-500) After creatinf domain and verifying all connection arguments setup_done_handler returns an error

33554450

I'm using OpenIPMI macroses for decoding error. This error is RMCP+ error, and real error code is

18

That error occures after sending RMCP+ Open Session Request and getting RMCP+ Open Session Response

This error occures not permanent and the multiple rebooting of Shelf Manager can solve this problem, but sometimes I need 10 or 15 reboots before I will be succesfully connected to ShMM.

Does somebody know, what that error means? Thanks in advance.

È stato utile?

Soluzione

The connection can be established only by proper using of connection method.

Early, I used a method

ipmi_args_setup_con();

with specific setup args. Now I'm using the concreate method

ipmi_ip_setup_con();

And it works all time.

Hope, that it will be helpfully for someone.