Pergunta

Desejo implantar um aplicativo da web de serviço (PWA) do Project Server 2010 no SharePoint 2010.Após todas as etapas, na etapa de provisionamento ela não termina.No 'Visualizador de Eventos' existe um evento por ID:17173 a cada 2 segundos!

Starting up database 'ProjectServer_Published'.

e em detalhes:

+ System 

- Provider 

[ Name]  MSSQL$SHAREPOINT 

- EventID 17137 

[ Qualifiers]  16384 

Level 4 

Task 2 

Keywords 0x80000000000000 

- TimeCreated 

[ SystemTime]  2012-10-20T11:27:29.000000000Z 

EventRecordID 18626 

Channel Application 




- EventData 

ProjectServer_Published 
    F14200000A000000160000005300480041005200450050004F0049004E0054005C005300480041005200450050004F0049004E0054000000070000006D00610073007400650072000000 


 --------------------------------------------------------------------------------

Binary data:


In Words

0000: 000042F1 0000000A 00000016 00480053 
0008: 00520041 00500045 0049004F 0054004E 
0010: 0053005C 00410048 00450052 004F0050 
0018: 004E0049 00000054 00000007 0061006D 
0020: 00740073 00720065 0000  


In Bytes

0000: F1 42 00 00 0A 00 00 00   ñB......
0008: 16 00 00 00 53 00 48 00   ....S.H.
0010: 41 00 52 00 45 00 50 00   A.R.E.P.
0018: 4F 00 49 00 4E 00 54 00   O.I.N.T.
0020: 5C 00 53 00 48 00 41 00   \.S.H.A.
0028: 52 00 45 00 50 00 4F 00   R.E.P.O.
0030: 49 00 4E 00 54 00 00 00   I.N.T...
0038: 07 00 00 00 6D 00 61 00   ....m.a.
0040: 73 00 74 00 65 00 72 00   s.t.e.r.
0048: 00 00                     ..

E este é o arquivo de log:

10/20/2012 15:24:16.93  Microsoft.Office.Project.Server (0x1814)    0x0E20  Project Server  General         8zd0    Medium  [SERVICE]    ProjectEventService14: Not starting ExecProcess for ServiceApp: 60739e6d-8645-485a-8ef0-e8217e80c87f  No sites defined 
10/20/2012 15:25:16.61  Microsoft.Office.Project.Server (0x1844)    0x0AF4  Project Server  Provisioning    8zdn    Medium  [SERVICE] ProjectQueueService14: Getting list of Sites for ServiceApp: 60739e6d-8645-485a-8ef0-e8217e80c87f 
10/20/2012 15:25:16.61  Microsoft.Office.Project.Server (0x1844)    0x0AF4  Project Server  General         8zdb    High    [SERVICE] ProjectQueueService14: ProcessWatcher signaled    
10/20/2012 15:25:16.61  Microsoft.Office.Project.Server (0x1844)    0x0AF4  Project Server  General         8zdk    High    [SERVICE] ProjectQueueService14: ProcessWatcher restarting service for 60739e6d-8645-485a-8ef0-e8217e80c87f PID: -1 
10/20/2012 15:25:16.61  Microsoft.Office.Project.Server (0x1844)    0x0AF4  Project Server  Provisioning    8zdn    Medium  [SERVICE] ProjectQueueService14: Getting list of Sites for ServiceApp: 60739e6d-8645-485a-8ef0-e8217e80c87f 
10/20/2012 15:25:16.61  Microsoft.Office.Project.Server (0x1844)    0x0AF4  Project Server  General         8zd0    Medium  [SERVICE] ProjectQueueService14: Not starting ExecProcess for ServiceApp: 60739e6d-8645-485a-8ef0-e8217e80c87f  No sites defined    
10/20/2012 15:25:16.94  Microsoft.Office.Project.Server (0x1814)    0x0E20  Project Server  General         8zdb    High    [SERVICE] ProjectEventService14: ProcessWatcher signaled    
10/20/2012 15:25:16.94  Microsoft.Office.Project.Server (0x1814)    0x0E20  Project Server  General         8zdk    High    [SERVICE] ProjectEventService14: ProcessWatcher restarting service for 60739e6d-8645-485a-8ef0-e8217e80c87f PID: -1 
10/20/2012 15:25:16.94  Microsoft.Office.Project.Server (0x1814)    0x0E20  Project Server  Provisioning    8zdn    Medium  [SERVICE] ProjectEventService14: Getting list of Sites for ServiceApp: 60739e6d-8645-485a-8ef0-e8217e80c87f 
10/20/2012 15:25:16.94  Microsoft.Office.Project.Server (0x1814)    0x0E20  Project Server  General         8zd0    Medium  [SERVICE] ProjectEventService14: Not starting ExecProcess for ServiceApp: 60739e6d-8645-485a-8ef0-e8217e80c87f  No sites defined    

Qual é o problema?Não há erro nem aviso.

Foi útil?

Solução 2

Resolvido!A causa foi uma versão ruim do MSSQL.Reinstalei o "Microsoft SQL Sever 2008 RT" e não houve nenhum problema.

Outras dicas

Experimente o seguinte:

  1. Serviço Stop & Start Project Application (certifique-se de que o serviço Project também tenha sido iniciado)
  2. Certifique-se de que o site do PWA tenha associações de aplicativo de serviço com o aplicativo de serviço do Project Server
  3. Se possível, exclua o aplicativo de serviço do Project Server e crie um novo com a permissão apropriada
  4. 'LINEAR\sp2010rtm' - Adicione esta conta ao grupo de administradores locais e verifique o status.

Para mais informações confira este link:

Mesmo problema resolvido em fórum diferente

Espero que tenha ajudado :)

Licenciado em: CC-BY-SA com atribuição
Não afiliado a sharepoint.stackexchange
scroll top